CMC Power Information

The following MIB tables provide information on the chassis power.
Table 1. DRsChassisIndexThe following table provides information about DRsChassisIndex.
Name drsChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only
Table 2. DRsPotentialPowerThe following table provides information about DRsPotentialPower.
Name drsPotentialPower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2
Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on.
Syntax DellPowerReading
Access Read-only
Table 3. DRsIdlePowerThe following table provides information about DRsIdlePower.
Name drsIdlePower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3
Description Defines the power (in watts) required by the chassis infrastructure, along with the minimum power requirements for all systems currently turned on.
Syntax DellPowerReading
Access Read-only
Table 4. DRsMaxPowerSpecificationThe following table provides information about DRsMaxPowerSpecification.
Name drsMaxPowerSpecification
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.4
Description Defines the power limit (in watts) at which server throttling takes place.
Syntax DellPowerReading
Access Read-only
Table 5. DRsPowerSurplusThe following table provides information about DRsPowerSurplus.
Name drsPowerSurplus
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5
Description Defines the power surplus (in watts) remaining above the drsPotentialPower reading.
Syntax DellPowerReading
Access Read-only
Table 6. DRsKWhCumulativeThe following table provides information about DRsKWhCumulative.
Name drsKWhCumulative
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6
Description Defines the cumulative chassis power usage (in KWh) since last reset.
Syntax DellPowerReading
Access Read-only
Table 7. DRsKWhCumulativeTimeThe following table provides information about DRsKWhCumulativeTime.
Name drsKWhCumulativeTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7
Description Defines the timestamp of the most recent chassis power accumulator reset.
Syntax DellTimestamp
Access Read-only
Table 8. DRsWattsPeakUsageThe following table provides information about DRsWattsPeakUsage.
Name drsWattsPeakUsage
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8
Description Defines the chassis peak power usage (in watts) since last reset.
Syntax DellPowerReading
Access Read-only
Table 9. DRsWattsPeakTimeThe following table provides information about DRsWattsPeakTime.
Name drsWattsPeakTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9
Description Defines the timestamp of the most recent chassis peak power usage.
Syntax DellTimestamp
Access Read-only
Table 10. DRsWattsMinUsageThe following table provides information about DRsWattsMinUsage.
Name drsWattsMinUsage
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10
Description Defines the chassis minimum power usage (in watts) since last reset.
Syntax DellPowerReading
Access Read-only
Table 11. DRsWattsMinTimeThe following table provides information about DRsWattsMinTime.
Name drsWattsMinTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11
Description Defines the time stamp of the most recent chassis minimum power usage.
Syntax DellPowerReading
Access Read-only
Table 12. DRsWattsResetTimeThe following table provides information about DRsWattsResetTime.
Name drsWattsResetTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12
Description Defines the time stamp of the most recent reset of the chassis minimum/maximum watts readings.
Syntax DellTimestamp
Access Read-only
Table 13. DRsWattsReadingThe following table provides information about DRsWattsReading.
Name drsWattsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13
Description Defines the instantaneous chassis power usage (in watts).
Syntax DellPowerReading
Access Read-only
Table 14. DRsAmpsReadingThe following table provides information about DRsAmpsReading
Name drsAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14
Description Defines the instantaneous chassis current usage (in watts).
Syntax DellPowerReading
Access Read-only

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\