The System Trap Group contains traps that fall under the System event category.
Table 1. Amperage Probe TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2AmperageProbeNormal
2179 Current sensor reading is within range. Status Events Amperage Informational
alert2AmperageProbeWarning
2178 Current sensor has detected a warning value. Status Events Amperage Minor
alert2AmperageProbeFailure
2177 Current sensor has detected a failure value. Error Events Amperage Critical
Table 2. Battery TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2BatteryNormal
2227 Battery state has returned to normal; or battery presence had been detected. Status Events Battery Informational
alert2BatteryWarning
2226 Battery is low. Status Events Battery Minor
alert2BatteryFailure
2225 Battery has failed or battery is absent. Error Events Battery Critical
Table 3. Cable TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2CableFailure
2393 Cable failure. Error Events Cable Critical
Table 4. CMC TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2CMCWarning
2546 Chassis Management Controller detected a warning. Status Events CMC Minor
alert2CMCFailure
2545 Chassis Management Controller detected an error. Error Events CMC Critical
Table 5. Fan TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2FanInformation
2155 Fan information. Status Events Fan Informational
alert2FanWarning
2154 Fan warning. Status Events Fan Minor
alert2FanFailure
2153 Fan failure. Error Events Fan Critical
Table 6. Hardware Configuration TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2HardwareConfigurationInformation
2331 Hardware configuration information. Status Events Hardware Configuration Informational
alert2HardwareConfigurationWarning
2330 Hardware configuration warning. Status Events Hardware Configuration Minor
alert2HardwareConfigurationFailure
2329 Hardware configuration failure or critical event. Error Events Hardware Configuration Critical
Table 7. IO Virtualization TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2IOVirtualizationWarning
2554 IO Virtualization warning. Status Events IO Virtualization Minor
alert2IOVirtualizationFailure
2553 IO Virtualization failure or critical event. Error Events IO Virtualization Critical
Table 8. Link Status TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2LinkStatusInformation
2251 Link status information. Status Events Link Status Informational
alert2LinkStatusWarning
2250 Link status warning.Status EventsLink Status Minor
alert2LinkStatusFailure
2249 Link status failure or critical event. Error Events Link Status Critical
Table 9. Power Supply TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2PowerSupplyNormal
2187 Power supply has returned to normal. Status Events Power Supply Informational
alert2PowerSupplyWarning
2186 Power supply has detected a warning. Status Events Power Supply Minor
alert2PowerSupplyFailure
2185 Power supply has detected a failure. Error Events Power Supply Critical
alert2PowerSupplyRedundancyPolicyChanged
8331PSU redundancy policy changed.Status EventsPower Supply Informational
Table 10. Power Supply Absent TrapThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2PowerSupplyAbsent
2465 Power supply is absent. Error Events Power Supply Critical
Table 11. Power Usage TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2PowerUsageInformation
2275 Power usage information. Status Events Power Supply Informational
alert2PowerUsageWarning
2274 Power Usage Warning. Status Events Power Supply Minor
alert2PowerUsageFailure
2273 Power Usage Failure. Error Events Power Supply Critical
Table 12. Redundancy TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2RedundancyInformation
2475 Redundancy information. Status Events Redundancy Informational
alert2RedundancyDegraded
2474 Redundancy is degraded. Status Events Redundancy Minor
alert2RedundancyLost
2473 Redundancy is lost. Error Events Redundancy Critical
Table 13. Security Event TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2SecurityInformation
2387 Security information. Status Events Security Informational
alert2SecurityWarning
2386Security WarningStatus EventsSecurity Minor
alert2SecurityFailure.
2385 Security failure or critical event. Error Events Security Critical
Table 14. System Event Log TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2SystemEventLogInformation
2379 System Event Log information. Status Events System Event Log Informational
alert2SystemEventLogWarning
2378 System Event Log warning. Status Events System Event Log Minor
alert2SystemEventLogFailure
2377 System Event Log failure or critical event. Error Events System Event Log Critical
Table 15. Software Configuration TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2SoftwareConfigurationInformation
2339 Software configuration information. Status Events Software Configuration Informational
alert2SoftwareConfigurationWarning
2338 Software configuration warning. Status Events Software ConfigurationMinor
alert2SoftwareConfigurationFailure
2337Software Configuration Failure.Error EventsSoftware ConfigurationCritical
Table 16. Temperature Probe TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2TemperatureProbeNormal
2163 Temperature sensor value is within range. Status Events Temperature Informational
alert2TemperatureProbeWarning
2162 Temperature sensor has detected a warning value. Status Events Temperature Minor
alert2TemperatureProbeFailure
2161 Temperature sensor has detected a failure value. Error Events Temperature Critical
alert2IOMTemperatureExceeded
8305I/O Module <iom slot name> temperature exceeded operating range.Error EventsTemperature Critical
alert2Unable2ReadTemperatureSensors
8306Unable to read planar board temperature sensors. The cooling has been increased to safeguard the system.Error EventsTemperature Minor
Table 17. Voltage Probe TrapsThe following tables describes the Trap ID, Description, Category, Sub Category and Severity of the trap
TrapID Description Category SubCategory Severity
alert2VoltageProbeNormal
2171 Voltage sensor reading is within range. Status Events Voltage Informational
alert2VoltageProbeWarning
2170 Voltage sensor has detected a warning value. Status Events Voltage Minor
alert2VoltageProbeFailure
2169 Voltage sensor has detected a failure value. Error Events Voltage Critical