Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

SNMP Reference Guide for iDRAC, Chassis Management Controller and OpenManage Enterprise - Modular Management Software 1.30.00

PDF

Enclosure Power Supply Table

The objects provide information about the Enclosure Power Supply group in storage.

NOTE The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.1.
Table 1. Enclosure Power Supply NumberThe following table is described in the order of name, object ID, description, syntax, and then the access level.
Name enclosurePowerSupplyNumber
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1
Description Instance number of this power supply unit.
Syntax INTEGER
Access read-only
Table 2. Enclosure Power Supply NameThe following table is described in the order of name, object ID, description, syntax, and then the access level.
Name enclosurePowerSupplyName
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2
Description The power supply unit's name as represented in Storage Management.
Syntax DisplayString
Access read-only
Table 3. Enclosure Power Supply StateThe following table is described in the order of name, object ID, description, syntax, and then the access level.
Name enclosurePowerSupplyState
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4
Description The current state of this power supply unit. Possible states:
  1. The current state could not be determined

  2. The power supply unit is operating normally

  3. The power supply unit has encountered a hardware problem or is not responding

  4. The power supply unit is no longer connected to the enclosure or there exists a problem communicating to it

  5. The power supply unit is unstable

Syntax INTEGER
Access read-only
Table 4. Enclosure Power Supply Part NumberThe following table is described in the order of name, object ID, description, syntax, and then the access level.
Name enclosurePowerSupplyPartNumber
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7
Description The part number of the power supply unit.
Syntax DisplayString
Access read-only
Table 5. Enclosure Power Supply Component StatusThe following table is described in the order of name, object ID, description, syntax, and then the access level.
Name enclosurePowerSupplyComponentStatus
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9
Description The status of the power supply unit itself without the propagation of any contained component status. Possible values:
  1. Other

  2. Unknown

  3. OK

  4. Non-critical

  5. Critical

  6. Non-recoverable

Syntax ObjectStatusEnum
Access read-only
Table 6. Enclosure Power Supply FQDDThe following table is described in the order of name, object ID, description, syntax, and then the access level.
Name enclosurePowerSupplyFQDD
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15
Description The power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
Syntax FQDDString
Access read-only
Table 7. Enclosure Power Supply Display NameThe following table is described in the order of name, object ID, description, syntax, and then the access level.
Name enclosurePowerSupplyDisplayName
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16
Description The power supply unit's friendly FQDD as represented in Storage Management.
Syntax DisplayString
Access read-only