Configure an authentication failure VLAN for users and devices that fail 802.1X authentication.

Syntax dot1x auth-fail-vlan vlan-id [max-attempts number]

To delete the authentication failure VLAN, use the no dot1x auth-fail-vlan vlan-id [max-attempts number] command.

Parameters
vlan-id Enter the VLAN Identifier. The range is from 1 to 4094.
max-attempts number (OPTIONAL) Enter the keywords max-attempts followed number of attempts desired before authentication fails. The range is from 1 to 5. The default is 3.
Defaults 3 attempts
Command Modes CONFIGURATION ( conf-if-interface-slot/port)
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information

If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached. If the authentication fails after all allowed attempts, the interface moves to the authentication failed VLAN.

After the authentication VLAN is assigned, the port-state must be toggled to restart authentication. Authentication occurs at the next reauthentication interval ( dot1x reauthentication).

Related Commands

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"