Set the amount of time the interface waits in the Listening state and the Learning state before transitioning to the Forwarding state.

Syntax vlan vlan-id forward-delay seconds

To return to the default setting, use the no vlan forward-delay command.

Parameters
vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094.
forward-delay seconds Enter the keywords forward-delay then the time interval, in seconds, that the system waits before transitioning PVST+ to the forwarding state. The range is from 4 to 30 seconds. The default is 15 seconds.
Defaults 15 seconds
Command Modes CONFIGURATION (conf-pvst)
Supported Modes Full—Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Related Commands

vlan bridge-priority — sets the bridge-priority value.

vlan hello-time — changes the time interval between BPDUs.

vlan max-age — changes the time interval before PVST+ refreshes.

show spanning-tree pvst — displays the PVST+ configuration.


Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"