PowerStore: Procedure for adding drives on 500T
Summary: The KB describes the recommended procedure for adding drives on a PowerStore 500T to avoid service disruption.
Instructions
Overview
PowerStore 500T has a software issue that may lead to a single node reboot and sometimes both nodes may reboot leading to service disruption.
- The KB is intended to only avoid the service disruption (both nodes reboot simultaneously).
- For more details on the issue see PowerStore: Drive Addition May Cause Node Reboot on 500T.
Target Audience
Before You begin
This procedure is only relevant if Slot 12 or above are to be added to a PowerStore 500T base enclosure (DPE) only.
-
This procedure is not relevant when adding drives to a Disk Enclosure (DAE).
-
This procedure is not relevant when adding drives to slots below 12 on the DPE.
- This procedure is intended for PowerStore 500T running PowerStoreOS 3.5.0 to LTS-v4.1.0.3
Note: If adding drives to a PowerStore cluster at code levels below PowerStoreOS LTS-v4.1.x, also review the following KBs relating to the need to update DriveDB.json:
Contact Dell Technical Support for questions or assistance.
Reference this KB Article in the Service Request for expedited handling.
Pre-requisites
Warning: If the drives to be added are different size than the existing drives, contact Dell Support.
- Verify that there are no major or critical alerts. Fix any outstanding alerts before the procedure.
- Download the latest PowerStore Health Check and verify that there are no outstanding issues on the appliance. Fix any outstanding issues.
For more information about PowerStore Health Check, see PowerStore: How to use the System Check feature. - Important: Make sure when adding drives to wait a minimum of 10 seconds between each drive (excluding slot 13 that requires waiting 10 minutes after adding slot-12).
Cautions
When to Contact Dell Services
- If the appliance or PowerStore Manager is not responding.
- If a node unexpectedly reboots.
DO NOT
- Remove or attempt to reseat any component without Dell Services approval.
- Reboot a node or run another procedure not listed in this KB.
Notice: Failure to adhere to the above warning may lead to service disruption and potential data integrity issues.
Procedure
- Add all drives up to (and including) Slot-12.
- Wait 10 minutes and monitor the system before adding the drive to slot-13.
- Make sure all the drives are detected and no outstanding issue (no outstanding alert, no unexpected node reboot, hosts have access to all paths)
If a node reboots at this stage, Contact Dell Technical Support for assistance.
DO NOT proceed with any additional activity on this appliance!
- Add the remaining drives.
- Make sure the drives are detected and no outstanding issue (no outstanding alert, no unexpected node reboot, hosts have access to all paths)
- If a node reboots at this stage, Contact Dell Technical Support for assistance.
- DO NOT proceed with any additional activity on this appliance!