VNX: Single SP panic from Bugcheck 0340404B SAS_CTLR_API_SPC_MSGU_TICK_COUNT_FAIL (Dell EMC Correctable)
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
SPB has encountered Bugcheck code 0340404b on xx/xx/xxxx xx:xx:xx.
B 03/01/16 09:23:43 DGSSP 76008106 The Storage Processor rebooted unexpectedly @ 09:08:17 on 03/01/2016: BugCheck 0, {0000000000000000, 000000000340404b, fffffa800e594f28, 0000000000000000}, Failing Instruction: 0xfffff88002ca0b90 in saspmc.sys loaded @ 0xfffff88002a50000 [SAS_CTLR_API_SPC_MSGU_TICK_COUNT_FAIL <SAS>] [ BugcheckCode: 340404b Definition not found, Bugcheck in: PFSM_PANIC_BASE ] B 03/01/16 09:23:23 DumpManager 41004100 Created Compressed Dump C:\dumps\SPB_CETV21531XXXXX_3dd0b2_03-01-2016_09-14-21.dmp.zip
Another error seen for this same bugcheck problem/fix
A 03/10/16 14:27:53 DGSSP 76008106 The Storage Processor rebooted unexpectedly @ 14:12:03 on 03/10/2016: BugCheck 0, {0000000000000000, 000000000340402e, fffff88181287f28, 0000000000000000}, Failing Instruction: 0xfffff880028ffb90 in saspmc.sys loaded @ 0xfffff880026af000 [SAS_CTLR_API_SPC_CMD_TIMEOUT <SAS>]
[ BugcheckCode: 340402e Definition not found, Bugcheck in: PFSM_PANIC_BASE ]
Cause
SAS_CTLR_API_SPC_MSGU_TICK_COUNT_FAIL - RCA: general exception fault in the SAS firmware.
SAS_CTLR_API_SPC_CMD_TIMEOUT - Command timeout during SAS chip reset
The SAS controller chip-set has taken a fatal error and reset, resulting in the SP bugcheck.
This issue will be addressed with SAS Controller firmware v2.13.43 and higher.
SAS_CTLR_API_SPC_CMD_TIMEOUT - Command timeout during SAS chip reset
The SAS controller chip-set has taken a fatal error and reset, resulting in the SP bugcheck.
This issue will be addressed with SAS Controller firmware v2.13.43 and higher.
Resolution
R33 VNX OE 05.33.009.5.155 contains the new firmware to address this issue.
Please upgrade to the latest version of R33 VNX OE.
Please upgrade to the latest version of R33 VNX OE.
Additional Information
There won't be business impact at the moment the single SP panic, the another SP was working normally to handle service IO.