Use a point-in-time (PIT) copy to rehydrate
PowerProtect Data Manager data in the
Cyber Recovery vault on an on-premises or AWS deployment.
You can initiate a
PowerProtect Data Manager recovery by using the
Cyber Recovery UI or the
CRCLI. You then complete the recovery from the
PowerProtect Data Manager application in the
Cyber Recovery vault.
NOTE: You can only run one recovery job per application at a time.
If you perform a
PowerProtect Data Manager automated recovery in the
Cyber Recovery vault, the following engines are not recovered:
Protection engine (NAS protection engine and TSDM data movers)
Search engine (Used for file search capability and restore)
Reporting engine (For backup reports)
The engines are separate VMs that are deployed by
PowerProtect Data Manager in the production system. Because the hostname/IP address for the vault
PowerProtect Data Manager system is different, the
Cyber Recovery software cannot deploy these engines during recovery.
When you initiate a recovery, the
Cyber Recovery software prepares your environment so that you can run a
PowerProtect Data Manager recovery from the application console. As part of this process, the software creates a production DD Boost username and password on the
DD system, and reboots the
PowerProtect Data Manager appliance. It also takes a VM snapshot of the
PowerProtect Data Manager appliance that you use to revert the
PowerProtect Data Manager software after you complete the recovery.
You can run a recovery check to ensure that a copy can be recovered. During the check, the state of the backup copy shows as
In-progress. When the
recovery check is completed successfully, the data backup copy shows as
Recoverable.
If the
recovery check fails, the state of the backup copy shows as
Failed. Alerts in the dashboard and an email message notify you of the state. The alerts are either:
Warning—The backup copy is partially recoverable.
Critical—The backup copy is unrecoverable.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\