DellEnclosureFanSensor

Description

An instance of DellEnclosureFanSensor contains Storage Enclosure fan sensor specific data.

URL

/redfish/v1/Dell/Chassis/<ComputerSystem-Id>/DellEnclosureFanSensor/<EnclosureFanSensor-Id>

Supported HTTP Method and Privileges

HTTP Method Required Privilege
GET Login
Property Type Read Only Description
CurrentReading integer Yes The current value indicated by the Sensor
DeviceDescription String Yes A string that contains the friendly Fully Qualified Device Description (FQDD), which is a property that describes the device and its location.
ElementName String Yes The user-friendly name for this instance.
FQDD String Yes The property shall represent Fully Qualified Device Description (FQDD).
LowerThresholdCritical Integer Yes The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If the CurrentReading is between LowerThresholdCritical and LowerThresholdFatal, the CurrentState is Critical.
LowerThresholdNonCritical Integer Yes The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If Current Reading is between LowerThresholdNonCritical and Upper ThresholdNonCritical, the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical and LowerThresholdCritical, the CurrentState is NonCritical.
PrimaryStatus String Yes PrimaryStatus provides a high-level status of the device.
RateUnits String Yes Specifies if the units returned by this Sensor are rate units. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). This is true unless this property (RateUnits) has a value other than "None". For example, if BaseUnits is Volts and the UnitModifier is -6, the units of the values returned are MicroVolts. But, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier. Any implementation of CurrentReading must be qualified with either a Counter or a Gauge qualifier, depending on the characteristics of the sensor being modeled. The property is not applicable.
ReadingUnits String Yes This property represents units of the current reading value, such as Degrees Celsius. This is the base unit of the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the UnitModifier is -6, the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.
State String Yes This property displays the current state of the device.
UnitModifier Integer Yes The unit multiplier for the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the Unit Modifier is -6, the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.
UpperThresholdCritical Integer Yes The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If the CurrentReading is between UpperThresholdCritical and UpperThresholdFatal, the CurrentState is Critical.
UpperThresholdNonCritical Integer Yes The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If the CurrentReading is between LowerThresholdNonCritical and UpperThresholdNonCritical, the Sensor is reporting a normal value. If the CurrentReading is between UpperThresholdNonCritical and UpperThresholdCritical, the CurrentState is NonCritical.
Table 1. Status codes
HTTP status code
200
404

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\