iDRAC9 Redfish API Guide Firmware version: 4.20.20.20

PDF

Temperature

Description

Above normal range.

URL

/redfish/v1/Chassis/<ComputerSystem-Id>/DellEnclosureTemperatureSensor/<EnclosureTemperatureSensor-Id>

Supported HTTP Method and Privileges

HTTP Method Required Privilege
POST ConfigureManager, Login
GET Login
PATCH ConfigureManager, Login

Supported Properties

Property Type Read only Description
CurrentReading Integer Yes The current value indicated by the sensor. The property value is in Degrees Celsius.
DeviceDescription String Yes A string that contains the friendly Fully Qualified Device Description (FQDD), which is a property that describes the device and its location.
ElementName String Yes The user-friendly name for this instance.
FQDD String Yes The property shall represent Fully Qualified Device Description.
LowerThresholdCritical Integer No The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, or Critical conditions. If the CurrentReading is below LowerThresholdCritical, the CurrentState is Critical. The lower critical threshold value in Degree Celsius.
LowerThresholdNonCritical Integer No The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, or Critical conditions. If Current Reading is between LowerThresholdNonCritical and Upper ThresholdNonCritical, the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical and LowerThresholdCritical, the CurrentState is NonCritical.The lower non-critical threshold value in Degree Celsius.
PrimaryStatus String Yes This property represents the status of the device.
RateUnits String Yes Specifies if the units returned by this Sensor are rate units. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). This is true unless this property (RateUnits) has a value different than "None". For example, if BaseUnits is Volts and the UnitModifier is -6, the units of the values returned are MicroVolts. But, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier. Any implementation of CurrentReading should be qualified with either a Counter or a Gauge qualifier, depending on the characteristics of the sensor being modeled. The property value is 0 (None).
ReadingUnits String Yes This property represents the units of current reading value. For example Degrees C.
SensorType String Yes The Type of the Sensor such as Fan, Voltage, or Temperature. The value is 2(Temperature).
State String Yes This property displays the current state of the device.
UnitModifier Integer Yes The unit multiplier for the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the Unit Modifier is -6, the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier. The property must have the value 0 denoting that the CurrentReading property value need not be multiplied by the UnitModifier property value.
UpperThresholdCritical Integer No The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, or Critical conditions. If the CurrentReading is above UpperThresholdCritical, the CurrentState is Critical. The upper critical threshold value in Degree Celsius.
UpperThresholdNonCritical Integer No The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, or Critical conditions. If the CurrentReading is between LowerThresholdNonCritical and UpperThresholdNonCritical, the Sensor is reporting a normal value. If the CurrentReading is between UpperThresholdNonCritical and UpperThresholdCritical, the CurrentState is NonCritical. The upper non-critical threshold value in Degree celsius.
HTTP Status Code Extended Information Error Code
200

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\