Dell PowerVault ME4 Series Storage System Administrator’s Guide

CIM Alerts

The implementation of alert indications allows a subscribing CIM client to receive events such as FC cable connects, Power Supply events, Fan events, Temperature Sensor events and Disk Drive events.

If the storage system’s SMI-S interface is enabled, the system will send events as indications to SMI-S clients so that SMI-S clients can monitor system performance. For information about enabling the SMI-S interface, see SMI-S configuration.

In a dual-controller configuration, both controller A and B alert events are sent via controller A’s SMI-S provider.

The event categories in the following table pertain to FRU assemblies and certain FRU components.

Table 1. CIM Alertindicationevents
FRU/Event category Corresponding SMI-S class Operational status values that would trigger alert conditions
Controller SMI_Controller Down, NotInstalled, OK
Hard Disk Drive SMI_DiskDrive Unknown, Missing, Error, Degraded, OK
Fan SMI_PSUFan Error, Stopped, OK
Power Supply SMI_PSU Unknown, Error, Other, Stressed, Degraded, OK
Temperature Sensor SMI_OverallTempSensor Unknown, Error, Other, Non-Recoverable Error, Degraded, OK
Battery/Super Cap SMI_SuperCap Unknown, Error, OK
FC Port SMI_FCPort Stopped, OK
SAS Port SMI_SASTargetPort Stopped, OK
iSCSI Port SMI_ISCSIEthernetPort Stopped, OK