Dell PowerVault ME4 Series Storage System Administrator’s Guide

Shutting down controllers

Perform a shut down before you remove a controller module from an enclosure, or before you power off its enclosure for maintenance, repair, or a move. Shutting down the storage controller in a controller module ensures that a proper failover sequence is used, which includes stopping all I/O operations and writing any data in write cache to disk. If you shut down the storage controller in both controller modules, hosts cannot access system data.

CAUTION:You can continue to use the CLI when either or both storage controllers are shut down, but some information might not be available.