RevisionNumber
|
Revision number for this MIB
|
220
|
UNumber
|
Top-level URL of this device, for example,
http://10.1.2.3. If a web server is not present on the device, this string is empty in accordance with the FA MIB2.2 Spec.
|
Default:
http://10.0.0.1
|
StatusChangeTime
|
Not supported
|
0
|
ConfigurationChangeTime
|
Not supported
|
0
|
ConnUnitTableChangeTime
|
Not supported
|
0
|
connUnitTable
|
Includes the following objects as specified by the FA MIB2.2 Spec:
|
connUnitId
|
Unique identification for this connectivity unit
|
Total of 16 bytes comprised of 8 bytes of the node WWN or similar serial number-based identifier (for example,1000005013b05211) with the trailing 8 bytes equal to zero
|
connUnitGlobalId
|
Same as
connUnitId
|
Same as
connUnitId
|
connUnitType
|
Type of connectivity unit
|
storage-subsystem (11)
|
connUnitNumports
|
Number of host ports in the connectivity unit
|
Number of host ports
|
connUnitState
|
Overall state of the connectivity unit
|
online (2) or unknown (1), as appropriate
|
connUnitStatus
|
Overall status of the connectivity unit
|
ok (3), warning (4), failed (5), or unknown (1), as appropriate
|
connUnitProduct
|
Connectivity unit vendor’s product model name
|
Model string
|
connUnitSn
|
Serial number for this connectivity unit
|
Serial number string
|
connUnitUpTime
|
Number of centiseconds since the last unit initialization
|
0 at startup
|
connUnitUrl
|
Same as
systemURL
|
Same as
systemURL
|
connUnitDomainId
|
Not used; set to all 1s as specified by the FA MIB2.2 Spec
|
0xFFFF
|
connUnitProxyMaster
|
Stand-alone unit returns yes for this object
|
yes (3) since this is a stand-alone unit
|
connUnitPrincipal
|
Whether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, returns unknown.
|
unknown (1)
|
connUnitNumSensors
|
Number of sensors in the connUnitSensorTable
|
33
|
connUnitStatusChangeTime
|
Same as
statusChangeTime
|
Same as
statusChangeTime
|
connUnitNumRevs
|
Number of revisions in the
connUnitRevsTable
|
16
|
connUnitNumZones
|
Not supported
|
0
|
connUnitModuleId
|
Not supported
|
16 bytes of 0s
|
connUnitName
|
Settable: Display string containing a name for this connectivity unit
|
Default: Uninitialized Name
|
connUnitInfo
|
Settable: Display string containing information about this connectivity unit
|
Default: Uninitialized Info
|
connUnitControl
|
Not supported
|
invalid (2) for an SNMP GET operation and not settable through an SNMP SET operation.
|
connUnitContact
|
Settable: Contact information for this connectivity unit
|
Default: Uninitialized Contact
|
connUnitLocation
|
Settable: Location information for this connectivity unit
|
Default: Uninitialized Location
|
connUnitEventFilter
|
Defines the event severity that will be logged by this connectivity unit. Settable only through the
PowerVault Manager.
|
Default: info (8)
|
connUnitNumEvents
|
Number of events currently in the
connUnitEventTable
|
Varies as the size of the Event Table varies
|
connUnitMaxEvents
|
Maximum number of events that can be defined in the
connUnitEventTable
|
400
|
connUnitEventCurrID
|
Not supported
|
0
|
connUnitRevsTable
|
Includes the following objects as specified by the FA MIB2.2 Spec:
|
connUnitRevsUnitId
|
connUnitId of the connectivity unit that contains this revision table
|
Same as
connUnitId
|
connUnitRevsIndex
|
Unique value for each
connUnitRevsEntry between 1 and
connUnitNumRevs
|
See
External details for certain FA MIB 2.2 objects
|
connUnitRevsRevId
|
Vendor-specific string identifying a revision of a component of the
connUnit
|
String specifying the code version. Reports “Not Installed or Offline” if module information is not available.
|
connUnitRevsDescription
|
Display string containing description of a component to which the revision corresponds
|
See
External details for certain FA MIB 2.2 objects
|
connUnitSensorTable
|
Includes the following objects as specified by the FA MIB2.2 Spec:
|
connUnitSensorUnitId
|
connUnitId of the connectivity unit that contains this sensor table
|
Same as
connUnitId
|
connUnitSensorIndex
|
Unique value for each
connUnitSensorEntry between 1 and
connUnitNumSensors
|
See
External details for certain FA MIB 2.2 objects
|
connUnitSensorName
|
Display string containing textual identification of the sensor intended primarily for operator use
|
See
External details for certain FA MIB 2.2 objects
|
connUnitSensorStatus
|
Status indicated by the sensor
|
ok (3), warning (4), or failed (5) as appropriate for FRUs that are present, or other (2) if FRU is not present.
|
connUnitSensorInfo
|
Not supported
|
Empty string
|
connUnitSensorMessage
|
Description the sensor status as a message
|
connUnitSensorName followed by the appropriate sensor reading. Temperatures display in both Celsius and Fahrenheit. For example, CPU Temperature (Controller Module A): 48C 118F). Reports “Not installed” or “Offline” if data is not available.
|
connUnitSensorType
|
Type of component being monitored by this sensor
|
See
External details for certain FA MIB 2.2 objects
|
connUnitSensorCharacteristic
|
Characteristics being monitored by this sensor
|
See
External details for certain FA MIB 2.2 objects
|
connUnitPortTable
|
Includes the following objects as specified by the FA MIB2.2 Spec:
|
connUnitPortUnitId
|
connUnitId of the connectivity unit that contains this port
|
Same as
connUnitId
|
connUnitPortIndex
|
Unique value for each
connUnitPortEntry between 1 and
connUnitNumPorts
|
Unique value for each port, between 1 and the number of ports
|
connUnitPortType
|
Port type
|
not-present (3), or n-port (5) for point-to-point topology, or l-port (6)
|
connUnitPortFCClassCap
|
Bit mask that specifies the classes of service capability of this port. If this is not applicable, returns all bits set to zero.
|
Fibre Channel ports return 8 for class-three
|
connUnitPortFCClassOp
|
Bit mask that specifies the classes of service that are currently operational. If this is not applicable, returns all bits set to zero.
|
Fibre Channel ports return 8 for class-three
|
connUnitPortState
|
State of the port hardware
|
unknown (1), online (2), offline (3), bypassed (4)
|
connUnitPortStatus
|
Overall protocol status for the port
|
unknown (1), unused (2), ok (3), warning (4), failure (5), notparticipating(6), initializing (7), bypass (8)
|
connUnitPortTransmitterType
|
Technology of the port transceiver
|
unknown (1) for Fibre Channel ports
|
connUnitPortModuleType
|
Module type of the port connector
|
unknown (1)
|
connUnitPortWwn
|
Fibre Channel World Wide Name (WWN) of the port if applicable
|
WWN octet for the port, or empty string if the port is not present
|
connUnitPortFCId
|
Assigned Fibre Channel ID of this port
|
Fibre Channel ID of the port. All bits set to 1 if the Fibre Channel ID is not assigned or if the port is not present
|
connUnitPortSn
|
Serial number of the unit (for example, for a GBIC). If this is not applicable, returns an empty string.
|
Empty string
|
connUnitPortRevision
|
Port revision (for example, for a GBIC)
|
Empty string
|
connUnitPortVendor
|
Port vendor (for example, for a GBIC)
|
Empty string
|
connUnitPortSpeed
|
Speed of the port in KByte per second (1 KByte = 1000 Byte)
|
Port speed in KByte per second, or 0 if the port is not present
|
connUnitPortControl
|
Not supported
|
invalid (2) for an SNMP GET operation and not settable through an SNMP SET operation
|
connUnitPortName
|
String describing the addressed port
|
See
External details for certain FA MIB 2.2 objects
|
connUnitPortPhysicalNumber
|
Port number represented on the hardware
|
Port number represented on the hardware
|
connUnitPortStatObject
|
Not supported
|
0 (No statistics available)
|
connUnitEventTable
|
Includes the following objects as specified by the FA MIB2.2 Spec:
|
connUnitEventUnitId
|
connUnitId of the connectivity unit that contains this port
|
Same as
connUnitId
|
connUnitEventIndex
|
Index into the connectivity unit’s event buffer, incremented for each event
|
Starts at 1 every time there is a table reset or the unit’s event table reaches its maximum index value
|
connUnitEventId
|
Internal event ID, incremented for each event, ranging between 0 and
connUnitMaxEvents
|
Starts at 0 every time there is a table reset or
connUnitMaxEvents is reached
|
connUnitREventTime
|
Real time when the event occurred, in the following format:
DDMMYYYY HHMMSS
|
0 for logged events that occurred prior to or at startup
|
connUnitSEventTime
|
sysuptime timestamp when the event occurred
|
0 at startup
|
connUnitEventSeverity
|
Event severity level
|
error (5), warning (6) or info (8)
|
connUnitEventType
|
Type of this event
|
As defined in CAPI
|
connUnitEventObject
|
Not used
|
0
|
connUnitEventDescr
|
Text description of this event
|
Formatted event, including relevant parameters or values
|
connUnitLinkTable
|
Not supported
|
N/A
|
connUnitPortStatFabricTable
|
Not supported
|
N/A
|
connUnitPortStatSCSITable
|
Not supported
|
N/A
|
connUnitPortStatLANTable
|
Not supported
|
N/A
|
SNMP Traps
|
The following SNMP traps are supported:
|
trapMaxClients
|
Maximum number of trap clients
|
3
|
trapClientCount
|
Number of trap clients currently enabled
|
1 if traps enabled; 0 if traps not enabled
|
connUnitEventTrap
|
This trap is generated each time an event occurs that passes the
connUnitEventFilter and the
trapRegFilter
|
N/A
|
trapRegTable
|
Includes the following objects per the FA MIB2.2 Spec:
|
trapRegIpAddress
|
IP address of a client registered for traps
|
IP address set by user
|
trapRegPort
|
User Datagram Protocol (UDP) port to send traps to for this host
|
162
|
trapRegFilter
|
Settable: Defines the trap severity filter for this trap host. The connUnit will send traps to this host that have a severity level less than or equal to this value.
|
Default: warning (6)
|
trapRegRowState
|
Specifies the state of the row
|
READ: rowActive (3) if traps are enabled. Otherwise rowInactive(2)
WRITE: Not supported
|