Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerVault ME4 Series Storage System Administrator’s Guide

FA MIB 2.2 SNMP behavior

The FA MIB 2.2 objects are in compliance with the FibreAlliance MIB v2.2 Specification (FA MIB2.2 Spec).

FA MIB 2.2 was never formally adopted as a standard, but it is widely implemented and contains many elements useful for storage products. This MIB generally does not reference and integrate with other standard SNMP information. It is implemented under the experimental subtree.

Significant status within the device includes such elements as its temperature and power sensors, the health of its storage elements such as virtual disks, and the failure of any redundant component including an I/O controller. While sensors can be individually queried, for the benefit of network management systems all the above elements are combined into an overall status sensor. This is available as the unit status (connUnitStatus for the only unit).

The revisions of the various components within the device can be requested through SNMP.

The port section is only relevant to products with Fibre Channel host ports.

The event table allows 400 recently-generated events to be requested. Informational, minor, major, or critical event types can be selected. Whichever type is selected enables the capture of that type and more severe events. This mechanism is independent of the assignment of events to be generated into traps.

The traps section is not supported. It has been replaced by an ability to configure trap destinations using the CLI or the PowerVault Manager. The statistics section is not implemented.

The following table lists the MIB objects, their descriptions and the value set in ME4 Series storage systems. Unless specified otherwise, objects are not settable.

Table 1. FA MIB 2.2 objects, descriptions, and values
Object Description Value
RevisionNumber Revision number for this MIB 220
UNumber Top-level URL of this device, for example, http://10.1.2.3. If a web server is not present on the device, this string is empty in accordance with the FA MIB2.2 Spec. Default: http://10.0.0.1
StatusChangeTime Not supported 0
ConfigurationChangeTime Not supported 0
ConnUnitTableChangeTime Not supported 0
connUnitTable Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitId Unique identification for this connectivity unit Total of 16 bytes comprised of 8 bytes of the node WWN or similar serial number-based identifier (for example,1000005013b05211) with the trailing 8 bytes equal to zero
connUnitGlobalId Same as connUnitId Same as connUnitId
connUnitType Type of connectivity unit storage-subsystem (11)
connUnitNumports Number of host ports in the connectivity unit Number of host ports
connUnitState Overall state of the connectivity unit online (2) or unknown (1), as appropriate
connUnitStatus Overall status of the connectivity unit ok (3), warning (4), failed (5), or unknown (1), as appropriate
connUnitProduct Connectivity unit vendor’s product model name Model string
connUnitSn Serial number for this connectivity unit Serial number string
connUnitUpTime Number of centiseconds since the last unit initialization 0 at startup
connUnitUrl Same as systemURL Same as systemURL
connUnitDomainId Not used; set to all 1s as specified by the FA MIB2.2 Spec 0xFFFF
connUnitProxyMaster Stand-alone unit returns yes for this object yes (3) since this is a stand-alone unit
connUnitPrincipal Whether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, returns unknown. unknown (1)
connUnitNumSensors Number of sensors in the connUnitSensorTable 33
connUnitStatusChangeTime Same as statusChangeTime Same as statusChangeTime
connUnitNumRevs Number of revisions in the connUnitRevsTable 16
connUnitNumZones Not supported 0
connUnitModuleId Not supported 16 bytes of 0s
connUnitName Settable: Display string containing a name for this connectivity unit Default: Uninitialized Name
connUnitInfo Settable: Display string containing information about this connectivity unit Default: Uninitialized Info
connUnitControl Not supported invalid (2) for an SNMP GET operation and not settable through an SNMP SET operation.
connUnitContact Settable: Contact information for this connectivity unit Default: Uninitialized Contact
connUnitLocation Settable: Location information for this connectivity unit Default: Uninitialized Location
connUnitEventFilter Defines the event severity that will be logged by this connectivity unit. Settable only through the PowerVault Manager. Default: info (8)
connUnitNumEvents Number of events currently in the connUnitEventTable Varies as the size of the Event Table varies
connUnitMaxEvents Maximum number of events that can be defined in the connUnitEventTable 400
connUnitEventCurrID Not supported 0
connUnitRevsTable Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitRevsUnitId connUnitId of the connectivity unit that contains this revision table Same as connUnitId
connUnitRevsIndex Unique value for each connUnitRevsEntry between 1 and connUnitNumRevs See External details for certain FA MIB 2.2 objects
connUnitRevsRevId Vendor-specific string identifying a revision of a component of the connUnit String specifying the code version. Reports “Not Installed or Offline” if module information is not available.
connUnitRevsDescription Display string containing description of a component to which the revision corresponds See External details for certain FA MIB 2.2 objects
connUnitSensorTable Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitSensorUnitId connUnitId of the connectivity unit that contains this sensor table Same as connUnitId
connUnitSensorIndex Unique value for each connUnitSensorEntry between 1 and connUnitNumSensors See External details for certain FA MIB 2.2 objects
connUnitSensorName Display string containing textual identification of the sensor intended primarily for operator use See External details for certain FA MIB 2.2 objects
connUnitSensorStatus Status indicated by the sensor

ok (3), warning (4), or failed (5) as appropriate for FRUs that are present, or other (2) if FRU is not present.

connUnitSensorInfo Not supported Empty string
connUnitSensorMessage Description the sensor status as a message connUnitSensorName followed by the appropriate sensor reading. Temperatures display in both Celsius and Fahrenheit. For example, CPU Temperature (Controller Module A): 48C 118F). Reports “Not installed” or “Offline” if data is not available.
connUnitSensorType Type of component being monitored by this sensor See External details for certain FA MIB 2.2 objects
connUnitSensorCharacteristic Characteristics being monitored by this sensor See External details for certain FA MIB 2.2 objects
connUnitPortTable Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitPortUnitId connUnitId of the connectivity unit that contains this port Same as connUnitId
connUnitPortIndex Unique value for each connUnitPortEntry between 1 and connUnitNumPorts Unique value for each port, between 1 and the number of ports
connUnitPortType Port type not-present (3), or n-port (5) for point-to-point topology, or l-port (6)
connUnitPortFCClassCap Bit mask that specifies the classes of service capability of this port. If this is not applicable, returns all bits set to zero. Fibre Channel ports return 8 for class-three
connUnitPortFCClassOp Bit mask that specifies the classes of service that are currently operational. If this is not applicable, returns all bits set to zero. Fibre Channel ports return 8 for class-three
connUnitPortState State of the port hardware unknown (1), online (2), offline (3), bypassed (4)
connUnitPortStatus Overall protocol status for the port

unknown (1), unused (2), ok (3), warning (4), failure (5), notparticipating(6), initializing (7), bypass (8)

connUnitPortTransmitterType Technology of the port transceiver unknown (1) for Fibre Channel ports
connUnitPortModuleType Module type of the port connector unknown (1)
connUnitPortWwn Fibre Channel World Wide Name (WWN) of the port if applicable WWN octet for the port, or empty string if the port is not present
connUnitPortFCId Assigned Fibre Channel ID of this port Fibre Channel ID of the port. All bits set to 1 if the Fibre Channel ID is not assigned or if the port is not present
connUnitPortSn Serial number of the unit (for example, for a GBIC). If this is not applicable, returns an empty string. Empty string
connUnitPortRevision Port revision (for example, for a GBIC) Empty string
connUnitPortVendor Port vendor (for example, for a GBIC) Empty string
connUnitPortSpeed Speed of the port in KByte per second (1 KByte = 1000 Byte) Port speed in KByte per second, or 0 if the port is not present
connUnitPortControl Not supported invalid (2) for an SNMP GET operation and not settable through an SNMP SET operation
connUnitPortName String describing the addressed port See External details for certain FA MIB 2.2 objects
connUnitPortPhysicalNumber Port number represented on the hardware Port number represented on the hardware
connUnitPortStatObject Not supported 0 (No statistics available)
connUnitEventTable Includes the following objects as specified by the FA MIB2.2 Spec:
connUnitEventUnitId connUnitId of the connectivity unit that contains this port Same as connUnitId
connUnitEventIndex Index into the connectivity unit’s event buffer, incremented for each event Starts at 1 every time there is a table reset or the unit’s event table reaches its maximum index value
connUnitEventId Internal event ID, incremented for each event, ranging between 0 and connUnitMaxEvents Starts at 0 every time there is a table reset or connUnitMaxEvents is reached
connUnitREventTime

Real time when the event occurred, in the following format:

DDMMYYYY HHMMSS
0 for logged events that occurred prior to or at startup
connUnitSEventTime sysuptime timestamp when the event occurred 0 at startup
connUnitEventSeverity Event severity level error (5), warning (6) or info (8)
connUnitEventType Type of this event As defined in CAPI
connUnitEventObject Not used 0
connUnitEventDescr Text description of this event Formatted event, including relevant parameters or values
connUnitLinkTable Not supported N/A
connUnitPortStatFabricTable Not supported N/A
connUnitPortStatSCSITable Not supported N/A
connUnitPortStatLANTable Not supported N/A
SNMP Traps The following SNMP traps are supported:
trapMaxClients Maximum number of trap clients 3
trapClientCount Number of trap clients currently enabled 1 if traps enabled; 0 if traps not enabled
connUnitEventTrap

This trap is generated each time an event occurs that passes the connUnitEventFilter and the trapRegFilter

N/A
trapRegTable Includes the following objects per the FA MIB2.2 Spec:
trapRegIpAddress IP address of a client registered for traps IP address set by user
trapRegPort User Datagram Protocol (UDP) port to send traps to for this host 162
trapRegFilter Settable: Defines the trap severity filter for this trap host. The connUnit will send traps to this host that have a severity level less than or equal to this value. Default: warning (6)
trapRegRowState Specifies the state of the row

READ: rowActive (3) if traps are enabled. Otherwise rowInactive(2)

WRITE: Not supported


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\