由于缺少证书,NetWorker Web 用户界面无法获取控制面板的最新计数

Summary: NetWorker Web 用户界面 (NWUI) 生成错误“无法获取控制面板的最新计数 — 根据监控服务的状态获取活动计数时出错。”

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

成功登录 NWUI 后,用户界面显示错误:
Failed to fetch latest counts for Dashboard. Error in fetching count of activities based on status from Monitoring Service
 
显示错误的用户界面屏幕截图“无法获取控制面板的最新计数。

Cause

缺少证书别名 emcnwuimonitoring 在 Java cacerts 密钥库中。

  • Linux: 
    /opt/nre/java/latest/lib/security/cacerts
  • Windows: 
    %drive%:\Program Files\NRE\java\jre1.8.0_<xxx>\lib\security\cacerts

Resolution

导入 emcnwuimonitoring 证书(不需要关闭 NetWorker 服务。)

  • Linux: 
/opt/nre/java/latest/bin # keytool -import -alias emcnwuimonitoring -keystore /opt/nre/java/latest/lib/security/cacerts -storepass changeit -file /nsr/nwui/monitoring/app/conf/emcnwuimonitoring.cer
  • Windows:
%drive%:\Program Files\NRE\java\jre1.8.0_<xxx>\bin> keytool.exe -import -alias emcnwuimonitoring -keystore "C:\Program Files\NRE\java\jre1.8.0_<xxx>\lib\security\cacerts" -storepass changeit -file "%drive%:\Program Files\EMC NetWorker\nwui\monitoring\app\conf\emcnwuimonitoring.cer"