Dell Unity: Kontrola stavu před upgradem se nezdaří s chybou check_connectemc_sender_1 (oprava společností Dell)

Summary: Kontrola stavu před upgradem (PUHC) selže s chybou: ERROR_CODE=platform::check_connectemc_sender_1|Chyba|UPGRADE NEMŮŽE POKRAČOVAT.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

Kontrola stavu před upgradem (PUHC) selže s chybou: 
ERROR_CODE=platform::check_connectemc_sender_1|Error|
UPGRADE CANNOT PROCEED.
check_connectemc_sender_1
errors :0x1000300- Operation failed. Error code: 0x1000300 The requested object could not be found on the system. Recheck the command name. 0x6400bee - Failed to perform the operation because connect home has not been configured

Cause

Od verze Unity OE 5.3 již nejsou oznámení o připojení ConnectHome pomocí <serialNumber>@dell.com výchozí
.Při konfiguraci připojení ConnectHome zahrňte e-mailovou adresu z názvu domény systému nebo příslušnou e-mailovou adresu, která projde ověřením ze serveru SMTP. 

Aby bylo možné povolit aplikaci SupportAssist ve verzi 5.3 a novější, musí mít společnost ConnectEMC e-mailovou adresu odesílatele.

Resolution

Tento problém lze vyřešit dvěma způsoby.

1. Přeskočte PUHC a proveďte upgrade. E-mailovou adresu odesílatele přidejte později.
2. Přidejte nyní e-mailovou adresu odesílatele a poté proveďte upgrade.

Možnost 1: Přeskočte PUHC a proveďte upgrade
  1. Spusťte následující příkaz:
svc_skip_puhc
  1. Chcete-li přeskočit chybu, spusťte následující příkaz:
+58

50: flr::check_for_disk_transitions
51: flr::check_for_faulted_disks
52: flr::check_for_no_pulled_disks
53: flr::check_for_snaps_in_an_active_state
54: flr::check_movesession_exists
55: slic::check_for_slic_committed
56: platform::check_centralized_esrs_version
57: platform::check_unsupported_proxy
58: platform::check_connectemc_sender
  1. Po přeskočení check_connectemc_sender spusťte upgrade z rozhraní Unisphere.
  2. Přidejte původní e-mailovou adresu pro ConnectEMC.  (Viz níže)
2. možnost: Přidejte původní e-mailovou adresu a poté proveďte upgrade

Existují tři možnosti, jak přidat e-mailovou adresu odesílatele:
  1. Unisphere
  2. svc_connectemc příkazy
  3. Příkazy uemcli
Unisphere:


SMTP
svc_connectemc:
  1. Spuštěním níže uvedeného příkazu zobrazte stav ConnectEMC:
svc_connectemc -s

ConnectEMC: NOTRUNNING DISABLE
      2. Otestujte schopnost ConnectEMC odeslat zprávu podpoře pomocí následujícího příkazu:
spa:/cores/service/user# svc_connectemc -t

ERROR [spa]: Email (ConnectEMC) not configured
    3.  Spuštěním následujícího příkazu zobrazte podrobnosti o konfiguraci ConnectEMC:
svc_connectemc -g

INFO [spa]: SMTP Host: smtp.server.com
INFO [spa]: SENDER EMAIL: DP-Unity01@dell.com
INFO [spa]: EMC Destination Email: emailalert@emc.com
   4. Spuštěním níže uvedeného příkazu nastavte e-mailovou adresu, kterou bude ConnectEMC používat k odesílání výstrah:
05:57:12 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc -m DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
ERROR [spa]: Email (ConnectEMC) not configured. Please enable connetEMC first.
   5. Spuštěním níže uvedených příkazů povolte funkci ConnectEMC:
05:58:30 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc --enable 10.1XX.1XX.1X1 --sendermail DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
INFO [spa]: Enabling ConnectEMC
INFO [spa]: Verifying peer connectivity ...
INFO [spa]: copying connectEMC config to peer
INFO [spa]: Persisting SMTP server configuration
INFO [spa]: Persisting sender email address configuration
INFO [spa]: ConnectEMC has been enabled successfully.
  1. Po povolení funkce ConnectEMC otestujte připojení: 
    svc_connectemc -t
    INFO [spa]: Test Dialhome request 

uemcli:

  1. Spuštěním následujícího příkazu zobrazte aktuální konfiguraci:
    uemcli /sys/support/connecthome show -detail
    
    1:  Enabled       = yes
       SMTP server     = 10.1XX.1XX.1X1
       E-mail from address = (none)@emc.com 
       E-mail to address  = emailalert@emc.com
Pokud před povolením funkce ConnectEMC ověříte testovací příkaz, selže s chybou: 
Operation failed. Error code: 0x1000300
The requested object could not be found on the system. Recheck the command name. (Error Code:0x1000300)
      2.  Spuštěním níže uvedených příkazů povolte funkci ConnectEMC: 
uemcli -d 10.0.0.1 -u local/joe -p Password /sys/support/connecthome set –enable yes –smtpServer 10.10.22.22 -emailFromAddr DP-Unity01@dell.com
  1. Pokud po povolení funkce ConnectEMC provedete test, proběhne úspěšně:
    09:05:02 root@CKM002XXXXX929 spb:/cores/service/user# uemcli -u admin -securepassword /sys/support/connecthome test
    Password:
    Storage system address: 127.0.0.1
    Storage system port: 443
    HTTPS connection
    
    Remote certificate:
    Issuer:   CN=DP-UNITY01
    Subject:  CN=DP-UNITY01
    Valid from: 2020:06:14:07:13:27
    Valid to:  2023:06:14:07:13:27
    Serial:   00a382cb17422be9fd
    Id:     2957123456
    Would you like to:
     [1] Accept the certificate for this session
     [2] Reject the certificate
    Please input your selection (The default selection is [1]):
    Operation completed successfully.
4. Vypište aktuální podrobnosti po změně konfigurace:
uemcli /sys/support/connecthome show -detail

Please input your selection (The default selection is [1]):
1:  Enabled       = yes
   SMTP server     = 10.1XX.1XX.1X1
   E-mail from address = DP-Unity01@dell.com
   E-mail to address  = emailalert@emc.com

Additional Information