PowerScaleOneFS CLI Command Reference

isi devices smartfail

Defaults to isi devices drive smartfail. Smartfails a drive so you can remove it from a node.

Syntax

NOTE:You can smartfail a node by running the command isi devices node smartfail.
isi devices smartfail {<bay> | --lnum <integer> | --sled <string>}
        [--node-lnn <integer>]
        [{--force | -f}]
        [{--verbose | -v}]

Options

{<bay> | --lnum <integer>}
Specifies the bay number or LNUM (logical drive number) of the drive to smartfail.
--node-lnn <integer>
Specifies the LNN (logical node number) of the node that contains the drive you want to smartfail. If omitted, the specified drive in the local node will be smartfailed.
--sled <string>
Specifies the prefix for the location of the sled of drives on which to operate. Must be one of [A | B | C | D | E].
{--force | -f}
Smartfails the drive without asking for confirmation.
{--verbose | -v}
Displays more detailed information.