PowerScaleOneFS CLI Command Reference

isi security check settings modify

Modifies the security check configuration settings.

Syntax

isi security check settings modify
  [{--stig-path | -s} <string>]
  [--revert-stig-path]
  [{--action | -a} {celog | reboot | shutdown}]
  [--revert-action]
  [{--verbose | -v}]
  [{--help | -h}]
 

Options

--stig-path | -s<string>
The path for the STIG profile in use.
--revert-stig-path
Set value to system default for --stig-path.
--action | -a {celog | reboot | shutdown}
The action to take when a security check discovers an anomaly. Values are:
celogIssue an event to CELOG. The message contains the details of the security anomaly.
rebootReboot the node.
shutdownShut down the node.
--revert-action
Set value to system default for --action (celog).
--verbose | -v
Displays more detailed information.
--help | -h
Displays help for this command.