This table lists the operating and storage specifications of your
OptiPlex Small Form Factor 7010.
Airborne contaminant level: G1 as defined by ISA-S71.04-1985
Table 1. Computer environment
The following table lists the operating and storage environment conditions of
OptiPlex Small Form Factor 7010.
Description
Operating
Storage
Temperature range
10°C to 35°C (50°F to 95°F)
-40°C-70°C (-40°F-158°F)
Relative humidity (maximum)
20% to 80% (non-condensing, Max dew point temperature = 26°C)
5% to 95% (non-condensing, Max dew point temperature = 33°C)
Vibration (maximum)*
0.26 GRMS random at 5 Hz to 350 Hz
1.37 GRMS random at 5 Hz to 350 Hz
Shock (maximum)
Bottom/Right half-sine pulse 40G, 2 ms
105G, 2 ms half-sine pulse
Altitude range
-15.2 m to 3048 m (-49.8 ft to 10,000 ft)
-15.2 m to 10,668 m (-49.8 ft to 35,000 ft)
Airborne Contaminants
ISA-71 G1**: <300A/month copper coupon corrosion AND <200A/month of silver coupon corrosion
ISA-71 G1**: <300A/month copper coupon corrosion AND <200A/month of silver coupon corrosion
]
CAUTION:Operating and storage temperature ranges may differ among components, so operating or storing the device outside these ranges may impact the performance of specific components.
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse.