This chapter lists the traps sent by the Dell Networking Operating System (OS). Each trap is listed by the fields Message ID, Trap Type, and Trap Option.

Table 1. SNMP Traps and Error Messages
Message ID Trap Type Trap Option
COLD_START SNMP COLDSTART
%SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.    
WARM_START SNMP WARMSTART
     
COPY_CONFIG_COMPLETE SNMP NONE
SNMP Copy Config Command Completed    
LINK_DOWN SNMP LINKDOWN
%IFA-1-PORT_LINKDN: changed interface state to down:%d    
LINK_UP SNMP LINKUP
%IFA-1-PORT_LINKUP: changed interface state to up:%d    
AUTHENTICATION_FAIL SNMP AUTH
%SNMP-3-SNMP_AUTH_FAIL: SNMP Authentication failed.Request with invalid community string.    
EGP_NEIGHBOR_LOSS SNMP NONE
     
OSTATE_DOWN SNMP LINKDOWN

%IFM-1-OSTATE_DN: changed interface state to down:%s

%IFM-5-CSTATE_DN:Changed interface Physical state to down: %s

   
OSTATE_UP SNMP LINKUP

%IFM-1-OSTATE_UP: changed interface state to up:%s

%IFM-5-CSTATE_UP: Changed interface Physical state to up: %s

   
RMON_RISING_THRESHOLD SNMP NONE
%RPM0-P:CP %SNMP-4-RMON_RISING_THRESHOLD: RMON rising threshold alarm from SNMP OID <oid>    
RMON_FALLING_THRESHOLD SNMP NONE
%RPM0-P:CP %SNMP-4-RMON_FALLING_THRESHOLD: RMON falling threshold alarm from SNMP OID <oid>    
RMON_HC_RISHING_THRESHOLD SNMP NONE
%RPM0-P:CP %SNMP-4-RMON_HC_RISING_THRESHOLD: RMON high-capacity rising threshold alarm from SNMP OID <oid>    
RMON_HC_FALLING_THRESHOLD SNMP NONE
%RPM0-P:CP %SNMP-4-RMON_HC_FALLING_THRESHOLD: RMON high-capacity falling threshold alarm from SNMP OID <oid>    
RESV NONE NONE
N/A    
CHM_MIN_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MINOR_TEMP: Minor alarm: chassis temperature    
CHM_MIN_ALRM_TEMP_CLR ENVMON TEMP
%CHMRG-5-MINOR_TEMP_CLR: Minor alarm cleared: chassis temperature normal (%s %d temperature is within threshold of %dC)    
CHM_MAJ_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (%s temperature reaches or exceeds threshold of %dC)    
CHM_MAJ_ALRM_TEMP_CLR ENVMON TEMP
%CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared: chassis temperature lower (%s %d temperature is within threshold of %dC)    
TME_TASK_SUSPEND ENVMON NONE
%TME-2-TASK SUSPENDED: SUSPENDED - svce:%d - inst:%d - task:%s    
TME_TASK_TERM ENVMON NONE
%TME-2-ABNORMAL_TASK_TERMINATION: CRASH - task:%s %s    
CHM_CPU_THRESHOLD ENVMON NONE
%CHMGR-5-CPU_THRESHOLD: Cpu %s usage above threshold. Cpu5SecUsage (%d)    
CHM_CPU_THRESHOLD_CLR ENVMON NONE
%CHMGR-5-CPU_THRESHOLD_CLR: Cpu %s usage drops below threshold. Cpu5SecUsage (%d)    
CHM_MEM_THRESHOLD ENVMON NONE
%CHMGR-5-MEM_THRESHOLD: Memory %s usage above threshold. MemUsage (%d)    
CHM_MEM_THRESHOLD_CLR ENVMON NONE
%CHMGR-5-MEM_THRESHOLD_CLR: Memory %s usage drops below threshold. MemUsage (%d)    
MACMGR_STN_MOVE ENVMON NONE
%MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d    
VRRP_BADAUTH PROTO NONE

%RPM1-P:RP2 %VRRP-3-VRRP_BAD_AUTH: vrid-1 on Gi 11/12 rcvd pkt with authentication type mismatch.

%RPM1-P:RP2 %VRRP-3-VRRP_BAD_AUTH: vrid-1 on Gi 11/12 rcvd pkt with authentication failure

   
VRRP_GO_MASTER PROTO NONE
%VRRP-6-VRRP_MASTER: vrid-%d on %s entering MASTER    
VRRP_PROTOCOL_ERROR PROTO NONE
VRRP_PROTOERR: VRRP protocol error on %S    
BGP4_ESTABLISHED PROTO NONE
%TRAP-5-PEER_ESTABLISHED: Neighbor %a, state %s    
BGP4_BACKW_XSITION PROTO NONE
%TRAP-5-BACKWARD_STATE_TRANS: Neighbor %a, state %s    
ETS_TRAP_TYPE_MODULE_STATUS_CHA NGE ETS NONE

%DIFFSERV-5-ETS_TRAP_TYPE_MODULE_STATUS_CHANGE: ETS Module status changed to enabled

%DIFFSERV-5-ETS_TRAP_TYPE_MODULE_STATUS_CHANGE: ETS Module status changed to disabled

   
ETS_TRAP_TYPE_ADMIN_MODE_CHANGE ETS NONE

%DIFFSERV-5-ETS_TRAP_TYPE_ADMIN_MODE_CHANGE : ETS Admin mode changed to on for port %s

%DIFFSERV-5-ETS_TRAP_TYPE_ADMIN_MODE_CHANGE : ETS Admin mode changed to off for port %s

   
ETS_TRAP_TYPE_OPER_STATE_CHANGE ETS NONE

%DIFFSERV-5-ETS_TRAP_TYPE_OPER_STATE_CHANGE: ETS Oper state changed to init for port %s

%DIFFSERV-5-ETS_TRAP_TYPE_OPER_STATE_CHANGE: ETS Oper state changed to off for port %s

%DIFFSERV-5-ETS_TRAP_TYPE_OPER_STATE_CHANGE: ETS Oper state changed to recommended for port %s

%DIFFSERV-5-ETS_TRAP_TYPE_OPER_STATE_CHANGE: ETS Oper state changed to rxConfigSrc for port %s

   
ETS_TRAP_TYPE_PEER_STATE_CHANGE ETS NONE

%DIFFSERV-5-ETS_TRAP_TYPE_PEER_STATE_CHANGE : ETS Peer state changed to enabled for port %s

%DIFFSERV-5-ETS_TRAP_TYPE_PEER_STATE_CHANGE : ETS Peer state changed to disabled for port %s

   
PFC_TRAP_TYPE_MODULE_STATUS_CHANGE PFC NONE

%DIFFSERV-5-PFC_TRAP_TYPE_MODULE_STATUS_CHANGE: PFC Module status changed to enabled

%DIFFSERV-5-PFC_TRAP_TYPE_MODULE_STATUS_CHANGE: PFC Module status changed to disabled

   
PFC_TRAP_TYPE_ADMIN_MODE_CHANGE PFC NONE

%DIFFSERV-5-PFC_TRAP_TYPE_ADMIN_MODE_CHANGE : PFC Admin mode changed to on for port %s

%DIFFSERV-5-PFC_TRAP_TYPE_ADMIN_MODE_CHANGE : PFC Admin mode changed to off for port %s

   
PFC_TRAP_TYPE_OPER_STATE_CHANGE PFC NONE

%DIFFSERV-5-PFC_TRAP_TYPE_OPER_STATE_CHANGE: PFC Oper state changed to init for port %s

%DIFFSERV-5-PFC_TRAP_TYPE_OPER_STATE_CHANGE: PFC Oper state changed to off for port %s

%DIFFSERV-5-PFC_TRAP_TYPE_OPER_STATE_CHANGE: PFC Oper state changed to recommended for port %s

%DIFFSERV-5-PFC_TRAP_TYPE_OPER_STATE_CHANGE: PFC Oper state changed to rxConfigSrc for port %s

   
PFC_TRAP_TYPE_PEER_STATE_CHANGE PFC NONE

%DIFFSERV-5-PFC_TRAP_TYPE_PEER_STATE_CHANGE: PFC Peer state changed to enabled for port %s

%DIFFSERV-5-PFC_TRAP_TYPE_PEER_STATE_CHANGE: PFC Peer state changed to disabled for port %s

   
FIPS_MAX_FCF_LIMIT_RCH FIPS NONE
%FCOE-5-MAX_FCF_LIMIT_RCH: Number of FCFs reached maximum allowed limit in VLAN %d    
FIPS_MAX_ENODE_LIMIT_RCH FIPS NONE
%FCOE-5-MAX_ENODE_LIMIT_RCH: Number of ENodes reached maximum allowed limit in the system    
FIPS_MAX_SESSION_LIMIT_RCH FIPS NONE
%FCOE-5-MAX_SESSION_LIMIT_RCH: Number of sessions reached maximum allowed limit in the system    
FIPS_FCF_DROP FIPS NONE
%FCOE-5-FCF_DROP: New FCF(%d,%s) discovered in Vlan %d is dropped as max-FCF-limit per VLAN is reached    
FIPS_ENODE_DROP FIPS NONE
%FCOE-5-ENODE_DROP: New ENode(%d,%s) discovered in interface %s dropped as max-ENode-limit in system reached    
FIPS_SESSION_DROP FIPS NONE
%FCOE-5-SESSION_DROP: New session(%d,%s) request in interface %s dropped as max-session-limit in system reached    
FIPS_ACL_INSTALL_FAIL FIPS NONE
%FCOE-5-ACL_INSTALL_FAIL: problem in installing ACL entries due to no space or hardware failure    
CHMGR_ENT_LAST_CHANGE_TIME ENTITY NONE
No error messages. Time, at which there is a change in a physical entity, is logged.    

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"