Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Broadcast Storm Control

On the Aggregator, the broadcast storm control feature is enabled by default on all ports, and disabled on a port when an iSCSI storage device is detected. Broadcast storm control is re-enabled as soon as the connection with an iSCSI device ends.

Broadcast traffic on Layer 2 interfaces is limited or suppressed during a broadcast storm. You can view the status of a broadcast-storm control operation by using the show io-aggregator broadcast storm-control status command. You can disable broadcast storm control by using the no io-aggregator broadcast storm-control command.

Dell Networking OS Behavior: If broadcast traffic exceeds 1000 Mbps, the Aggregator limits it to 1000 Mbps per port-pipe.

Supported Modes

Standalone, PMUX, VLT, Stacking