Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Configuring Storm Control

The following configurations are available only in PMUX mode.

  1. To configure the percentage of broadcast traffic allowed on an interface, use the storm-control broadcast [ packets_per_second in] command from INTERFACE mode.
  2. To configure the percentage of multicast traffic allowed on an interface, use the storm-control multicast [ packets_per_second in] command from INTERFACE mode.
  3. To configure the percentage of unknown-unicast traffic allowed on an interface, use the storm-control unknown-unicast [ packets_per_second in] command from INTERFACE mode.