Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Management Interfaces

The IOM management interface has both a public IP and private IP address on the internal fabric D interface.

The public IP address is exposed to the outside world for Web GUI configurations/WSMAN and other proprietary traffic. You can statically configure the public IP address or obtain the IP address dynamically using the dynamic host configuration protocol (DHCP).

  • NOTE: When you shut down a management interface, connectivity to the interface’s private IP address is disabled.
You can access the full switch using:
  • Internal RS-232 using the chassis management controller (CMC). Telnet into CMC and do a connect -b switch-id to get console access to corresponding IOM.
  • External serial port with a universal serial bus (USB) connector (front panel): connect using the IOM front panel USB serial line to get console access (Labeled as USB B).
  • Telnet/others using the public IP interface on the fabric D interface.
  • CMC through the private IP interface on the fabric D interface.

The MXL switch system supports the management Ethernet interface as well as the standard interface on any front-end port. You can use either method to connect to the system.