Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Configuring a VLT Backup Link

To configure a VLT backup link, use the following command.

  1. Specify the management interface to be used for the backup link through an out-of-band management network. CONFIGURATION mode interface managementethernet slot/ port Enter the slot (0-1) and the port (0).
  2. Configure an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) and mask (/x) on the interface. MANAGEMENT INTERFACE mode {ip address ipv4-address/ mask | ipv6 address ipv6-address/ mask} This is the IP address to be configured on the VLT peer with the back-up destination command.
  3. Ensure that the interface is active. MANAGEMENT INTERFACE mode no shutdown
  4. Repeat Steps 1 to 3 on the VLT peer switch.
To set an amount of time, in seconds, to delay the system from restoring the VLT port, use the delay-restore command at any time. For more information, refer to VLT Port Delayed Restoration .