Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Establish Sessions on Port-Channels

To establish a session, you must enable BFD at interface level on both ends of the link, as shown in the following example. The session parameters do not need to match.

Figure 1. Establishing Sessions on Port-Channels Illustration of establishing sessions on port-channels.

To establish a session on a port-channel, use the bfd neighbor ip-address command in INTERFACE PORT-CHANNEL mode.

View the established sessions using the show bfd neighbors command, as shown in Changing Port-Channel Session Parameters .

Viewing Established Sessions for VLAN Neighbors

R2(conf-if-po-1)#bfd neighbors 2.2.2.1
                                 R2(conf-if-po-1)#do show bfd neighors
                                 * - Active session role
                                 Ad Dn - Admin Down
                                 C - CLI
                                 I - ISIS
                                 O - OSPF
                                 R - Static Route (RTM)
                                 V - VRRP
                                 LocalAddr RemoteAddr Interface State Rx-int Tx-int Mult Clients
                                 * 2.2.2.2   2.2.2.1    
                                 Po 1      Up    200    200    3     C
                              