Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Verifying the Configurations

When the port channel of the upstream switch is configured, the port channel on the FN IOM is up. A series of messages is logged on the system indicating port channel 128 and the ports connected to the servers downstream are up.

Changed interface state to up: Po 128
                              
                              Downstream interface cleared from UFD error-disabled: Te 0/1
                              Downstream interface cleared from UFD error-disabled: Te 0/2
                              Downstream interface cleared from UFD error-disabled: Te 0/3
                              …etc.
                              
                           

To verify the status, run the following commands:

Dell#show interfaces port-channel 128
                              Port-channel 128 is up, line protocol is up
                              
                           
Dell#show uplink-state-group
                              Uplink State Group: 1   Status: Enabled, Up
                           