Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Link Aggregation

Unlike IOA Automated modes (Standalone and VLT modes), the IOA Programmable MUX (PMUX) can support multiple uplink LAGs. You can provision multiple uplink LAGs. The I/O Aggregator auto-configures with link aggregation groups (LAGs) as follows:

  • All uplink ports are automatically configured in a single port channel (LAG 128).
  • Server-facing LAGs are automatically configured if you configure server for link aggregation control protocol (LACP)-based NIC teaming (Network Interface Controller (NIC) Teaming).

No manual configuration is required to configure Aggregator ports in the uplink or a server-facing LAG.

  • NOTE: Static LAGs are not supported on the SMUX Aggregator.
  • NOTE: In order to avoid loops, only disjoint VLANs are allowed between the uplink ports/uplink LAGs and uplink-to-uplink switching is disabled.

Supported Modes

Standalone, VLT, PMUX, Stacking