Ga naar hoofdinhoud
  • Snel en eenvoudig bestellen
  • Bestellingen en de verzendstatus bekijken
  • Een lijst met producten maken en openen
  • Beheer uw Dell EMC locaties, producten en contactpersonen op productniveau met Company Administration.

Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Marking Egress Packets with a DEI Value

On egress, you can set the DEI value according to a different mapping than ingress.

For ingress information, refer to Honoring the Incoming DEI Value .

To mark egress packets, use the following command.

Set the DEI value on egress according to the color currently assigned to the packet. INTERFACE mode dei mark {green | yellow} {0 | 1}

Example of Viewing DEI-Marking Configuration

To display the DEI-marking configuration, use the show interface dei-mark [ interface slot/port | linecard number port-set number] in EXEC Privilege mode.
Dell#show interface dei-mark
                                 
                                 Default CFI/DEI Marking: 0
                                 Interface Drop precedence CFI/DEI
                                 --------------------------------
                                 Gi 0/1    Green           0
                                 Gi 0/1    Yellow          1
                                 Gi 8/9    Yellow          0
                                 Gi 8/40   Yellow          0
                              