Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

FIP Snooping on VLANs

FIP snooping is enabled globally on an Aggregator on all VLANs:

  • FIP frames are allowed to pass through the switch on the enabled VLANs and are processed to generate FIP snooping ACLs.
  • FCoE traffic is allowed on VLANs only after a successful virtual-link initialization (fabric login FLOGI) between an ENode and an FCF. All other FCoE traffic is dropped.
  • Atleast one interface is auto-configured for FCF (FIP snooping bridge — FCF) mode on a FIP snooping-enabled VLAN. Multiple FCF trusted interfaces are auto-configured in a VLAN.
  • A maximum of eight VLANs are supported for FIP snooping on an Aggregator. FIP snooping processes FIP packets in traffic only from the first eight incoming VLANs.