Ga naar hoofdinhoud
  • Snel en eenvoudig bestellen
  • Bestellingen en de verzendstatus bekijken
  • Een lijst met producten maken en openen
  • Beheer uw Dell EMC locaties, producten en contactpersonen op productniveau met Company Administration.

Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Display the Logging Buffer and the Logging Configuration

To display the current contents of the logging buffer and the logging settings for the system, use the show logging command in EXEC privilege mode. When RBAC is enabled, the security logs are filtered based on the user roles. Only the security administrator and the system administrator can view the security logs.

Example of the show logging Command

Dell#show logging
                                 syslog logging: enabled
                                 Console logging: level Debugging
                                 Monitor logging: level Debugging
                                 Buffer logging: level Debugging, 40 Messages Logged, Size (40960 bytes)
                                 Trap logging: level Informational
                                 %IRC-6-IRC_COMMUP: Link to peer RPM is up
                                 %RAM-6-RAM_TASK: RPM1 is transitioning to Primary RPM.
                                 %RPM-2-MSG:CP1 %POLLMGR-2-MMC_STATE: External flash disk missing in 'slot0:'
                                 %CHMGR-5-CARDDETECTED: Line card 0 present
                                 %CHMGR-5-CARDDETECTED: Line card 2 present
                                 %CHMGR-5-CARDDETECTED: Line card 4 present
                                 %CHMGR-5-CARDDETECTED: Line card 5 present
                                 %CHMGR-5-CARDDETECTED: Line card 8 present
                                 %CHMGR-5-CARDDETECTED: Line card 10 present
                                 %CHMGR-5-CARDDETECTED: Line card 12 present
                                 %TSM-6-SFM_DISCOVERY: Found SFM 0
                                 %TSM-6-SFM_DISCOVERY: Found SFM 1
                                 %TSM-6-SFM_DISCOVERY: Found SFM 2
                                 %TSM-6-SFM_DISCOVERY: Found SFM 3
                                 %TSM-6-SFM_DISCOVERY: Found SFM 4
                                 %TSM-6-SFM_DISCOVERY: Found SFM 5
                                 %TSM-6-SFM_DISCOVERY: Found SFM 6
                                 %TSM-6-SFM_DISCOVERY: Found SFM 7
                                 %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: UP
                                 %TSM-6-SFM_DISCOVERY: Found SFM 8
                                 %TSM-6-SFM_DISCOVERY: Found 9 SFMs
                                 %CHMGR-5-CHECKIN: Checkin from line card 5 (type EX1YB, 1 ports)
                                 %TSM-6-PORT_CONFIG: Port link status for LC 5 => portpipe 0: OK portpipe 1: N/A
                                 %CHMGR-5-LINECARDUP: Line card 5 is up
                                 %CHMGR-5-CHECKIN: Checkin from line card 12 (type S12YC12, 12 ports)
                                 %TSM-6-PORT_CONFIG: Port link status for LC 12 => portpipe 0: OK portpipe 1: N/A
                                 %CHMGR-5-LINECARDUP: Line card 12 is up
                                 %IFMGR-5-CSTATE_UP: changed interface Physical state to up: So 12/8
                                 %IFMGR-5-CSTATE_DN: changed interface Physical state to down: So 12/8
                              

To view any changes made, use the show running-config logging command in EXEC privilege mode, as shown in the example for Configuring a UNIX Logging Facility Level.