Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Setting up VLT

The following figure shows the sample VLT topology.

Figure 1. Sample VLT TopologySample VLT Topology

In PMUX VLT, you can choose any uplink ports for configuring VLT.

  • NOTE: Ensure the connectivity to ToR from each Aggregator.
To enable VLT and verify the configuration, follow these steps.
  1. Enable VLT in node 1 and 2.stack-unit unit iom-mode vlt CONFIGURATION mode Dell(conf)#stack-unit 0 iom-mode vlt
  2. Verify the VLT configurations.show interface port-channel brief EXEC mode
    Dell# show interfaces port brief
                                        Codes: L - LACP Port-channel
                                        O - OpenFlow Controller Port-channel
                                        
                                        LAG      Mode  Status       Uptime      Ports          
                                        127  L2    up           00:18:22    Fo 0/33    (Up)<<<<<<<<ICL LAG
                                        Fo 0/37    (Up)
                                        L   128  L2    up           00:00:00    Fo 0/41    (Up)<<<<<<<<Uplink LAG   
                                     