PDF

Removing an Aggregator from a Stack

To remove an Aggregator from a stack, follow the below steps:

  1. Disconnect the stacking cables from the unit. The unit can be powered on or off and can be online or offline.
  2. Log on to the CLI and enter Global Configuration mode.
    Login: username
                                        Password: *****
                                        Dell> enable
                                        Dell# configure
                                     
  3. Configure the Aggregator to operate in standalone mode. CONFIGURATION stack-unit 0 iom-mode standalone
  4. Log on to the CLI and reboot each switch, one after another, in as short a time as possible. EXEC PRIVILEGE reload
The switch functions in standalone mode but retains the running and startup configuration that was last synchronized by the master switch while it operated as a stack unit.