Ga naar hoofdinhoud
  • Snel en eenvoudig bestellen
  • Bestellingen en de verzendstatus bekijken
  • Een lijst met producten maken en openen
  • Beheer uw Dell EMC locaties, producten en contactpersonen op productniveau met Company Administration.

Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Reconfiguring the Default VLT Settings (Optional)

To reconfigure the default VLT settings, use the following commands.

  1. Enter VLT-domain configuration mode for a specified VLT domain. CONFIGURATION mode vlt domain domain-id The range of domain IDs is from 1 to 1000.
  2. (Optional) After you configure the VLT domain on each peer switch on both sides of the interconnect trunk, by default, the system elects a primary and secondary VLT peer device. VLT DOMAIN CONFIGURATION mode primary-priority value To reconfigure the primary role of VLT peer switches, use the primary-priority command. To configure the primary role on a VLT peer, enter a lower value than the priority value of the remote peer. The priority values are from 1 to 65535. The default is 32768.
  3. (Optional) When you create a VLT domain on a switch, the system automatically creates a VLT-system MAC address used for internal system operations. VLT DOMAIN CONFIGURATION mode system-mac mac-address mac-address To explicitly configure the default MAC address for the domain by entering a new MAC address, use the system-mac command. The format is aaaa.bbbb.cccc. Also, reconfigure the same MAC address on the VLT peer switch. Use this command to minimize the time required for the VLT system to synchronize the default MAC address of the VLT domain on both peer switches when one peer switch reboots.
  4. (Optional) When you create a VLT domain on a switch, the system automatically assigns a unique unit ID (0 or 1) to each peer switch. VLT DOMAIN CONFIGURATION mode unit-id {0 | 1} To explicitly configure the default values on each peer switch, use the unit-id command. Configure a different unit ID (0 or 1) on each peer switch. Unit IDs are used for internal system operations. Use this command to minimize the time required for the VLT system to determine the unit ID assigned to each peer switch when one peer switch reboots.

Beoordeel deze inhoud

Nauwkeurig
Nuttig
Eenvoudig te begrijpen
Was dit artikel nuttig?
0/3000 characters
  Geef een beoordeling (1-5 sterren).
  Geef een beoordeling (1-5 sterren).
  Geef een beoordeling (1-5 sterren).
  Selecteer of het artikel nuttig is of niet.
  Opmerkingen mogen geen speciale tekens bevatten: <>() \