Items reported in periodic collections from servers

The items reported in the telemetry that is collected from servers vary depending on the:
  • Device type used to add the device in secure connect gateway.
  • Type of collection (manual, periodic, or service request).

The telemetry that is collected for a service request or for a manually initiated collection is more detailed in comparison with the telemetry that is collected during a periodic collection. For the complete list of attributes that are collected, see the Secure Connect Gateway 5.x — Virtual Edition Reportable Items available on the Secure Connect Gateway - Virtual Edition documentation page. The telemetry that is collected during periodic collections enables Dell Technologies to provide you an insight into your environment configuration with proactive firmware recommendations and other reports.

The following table provides a summary of the items reported in the collected telemetry during a periodic collection from a server:
Table 1. Items reported in a periodic collection from a serverThe following table identifies the items reported in periodic collections.
Items reported Device added in secure connect gateway with device type as Server / Hypervisor Device added in secure connect gateway with the device type as iDRAC
OMSA is installed on the device OMSA is not installed on the device
Memory Success iconclose iconSuccess icon
Memory Array Success iconclose iconSuccess icon
Memory Operating Mode Success iconclose iconclose icon
Memory Redundancy Success iconclose iconclose icon
Slot Success iconclose iconSuccess icon
Controller Success iconclose iconSuccess icon
Connector Success iconclose iconclose icon
PCIe-SSD-Extender Success iconclose iconSuccess icon
Enclosure Success iconclose iconSuccess icon
Array Disk Success iconclose iconSuccess icon
Intrusion Switch Success iconclose iconSuccess icon
Hardware Log Success iconclose iconSuccess icon
Main Chassis Success iconclose iconSuccess icon
Additional Information Success iconclose iconSuccess icon
Modular Enclosure Information Success iconclose iconSuccess icon
Firmware Success iconclose iconSuccess icon
Processor Success iconclose iconSuccess icon
Fan Success iconclose iconSuccess icon
Fan Redundancy Success iconclose iconSuccess icon
Temperature Success iconclose iconSuccess icon
Voltage Success iconclose iconSuccess icon
Power Supply Success iconclose iconSuccess icon
Power Supply Redundancy Success iconclose iconSuccess icon
Network Success iconclose iconSuccess icon
IPv4 Address Success iconclose iconclose icon
IPv6 Address Success iconclose iconclose icon
Network Team Interface Success iconclose iconclose icon
Interface Member Success iconclose iconclose icon
Remote Access Device Success iconclose iconSuccess icon
DRAC Information Success iconclose iconclose icon
Serial Over LAN Configuration Success iconclose iconSuccess icon
IPv6 Detail Success iconclose iconclose icon
User Setting Success iconclose iconSuccess icon
User Information Success iconclose iconSuccess icon
iDRAC User Privilege Success iconclose iconSuccess icon
DRAC User Privilege Success iconclose iconclose icon
Serial Port Configuration Success iconclose iconSuccess icon
NIC Configuration Success iconclose iconSuccess icon
Component Detail Success iconclose iconSuccess icon
Controller TTY Log Success iconclose iconSuccess icon
Operating System Success iconSuccess iconclose icon
NOTE:In a collection from an iDRAC, Controller TTY Log is available only if iDRAC firmware version 2.00.00.00 or later is installed on the server.