Dell PowerEdge R660 Installation and Service Manual

Installing the intrusion switch module

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the expansion card riser.
NOTE:Ensure that you note the routing of the cables as you remove them from the system board. Route the cables properly when you replace it to prevent the cables from being pinched or crimped.

Steps

  1. Align the guides on the intrusion switch module with the standoffs on the system.
  2. Slide the intrusion switch module into the slot in the system until firmly seated.
  3. Using a Phillips #2 screwdriver, tighten the screw on the intrusion switch module.
  4. Connect the intrusion switch cable to the connector on the rear I/O board.
    NOTE:The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
    Figure 1. Installing the intrusion switch module
    This image shows how to install the intrusion switch module.

Next steps

  1. Install the expansion card riser.
  2. Follow the procedure listed in After working inside your system.