跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Dell PowerEdge R660 Installation and Service Manual

Redundant OS Control

To view the Redundant OS Control screen, power on the system, press F2, and click System Setup Main Menu > System BIOS > Redundant OS Control.
Table 1. Redundant OS Control detailsThis table provides the details of the options available on the Redundant OS Control screen.
Option Description
Redundant OS Location Enables you to select a backup disk from the following devices:
  • None
  • SATA Ports in AHCI mode
  • BOSS PCIe Cards (Internal M.2 Drives)
  • Internal USB
    NOTE:RAID configurations and NVMe cards are not included, as BIOS does not have the ability to distinguish between individual drives in those configurations.
  • Internal SD card
Redundant OS State
NOTE:This option is disabled if Redundant OS Location is set to None.
When set to Visible, the backup disk is visible to the boot list and OS. When set to Hidden, the backup disk is disabled and is not visible to the boot list and OS. This option is set to Visible by default.
NOTE:BIOS disables the device in hardware, so it is not accessed by the OS.
Redundant OS Boot
NOTE:This option is disabled if Redundant OS Location is set to None or if Redundant OS State is set to Hidden.
When set to Enabled, BIOS boots to the device specified in Redundant OS Location. When set to Disabled, BIOS preserves the current boot list settings. This option is set to Disabled by default.

對此內容評分

準確
實用
易懂
這篇文章對您有用嗎?
0/3000 characters
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  本文章是否有幫助?請選擇。
  評語中不得包含下列特殊字元:<>()\