跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Dell PowerEdge R660 Installation and Service Manual

Removing the 14 x EDSFF E3.S drive backplane

Prerequisites

CAUTION:To prevent damage to the drives and backplane, remove the drives from the system before removing the backplane.
CAUTION:Note the number of each drive and temporarily label them before you remove the drive so that you can reinstall them in the same location.
NOTE:The procedure to remove the backplane is similar for all backplane configurations.
  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. If installed, remove the air shroud.
  4. Remove the drive backplane cover.
  5. Remove the drive carrier.
  6. Observe and disconnect the drive backplane cables from the connector on the system board and backplane.
    NOTE:Refer cable routing topic for more information.

Steps

  1. Using a Phillips #1 screwdriver, loosen the captive screw on the backplane module.
  2. Slide the backplane and lift it away from the system.
    NOTE:To avoid damaging the backplane, ensure that you move the control panel cables from the cable routing clips before removing the backplane.
    Figure 1. Removing the 14 xEDSFF E3.S drive backplane
    This image shows the removal of the 14 e3 drive backplane.

對此內容評分

準確
實用
易懂
這篇文章對您有用嗎?
0/3000 characters
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  本文章是否有幫助?請選擇。
  評語中不得包含下列特殊字元:<>()\