Dell PowerEdge R660 Installation and Service Manual

Installing the rear drive module

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. If installed, remove the air shroud.

Steps

  1. Align the rear drive module with the guide on the system board.
  2. Lower the rear drive module and slide it to the backward till it clicks.
  3. Using a Phillips #1 screwdriver, tighten the captive screws on the rear drive module.
    NOTE:The procedure to install the rear drive module is the same for liquid cooling module configuration.
    Figure 1. Installing the rear drive module

    This image shows Installing the rear drive module.

Next steps

  1. If removed, install the expansion card riser
  2. Connect all the cables to the rear drive module.
  3. Install the rear drives.
  4. If removed, replace the air shroud.
  5. Follow the procedure listed in After working inside your system.