Dell PowerEdge R660 Installation and Service Manual

Removing the left control panel

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the drive backplane cover.
  4. If installed, remove the air shroud.

Steps

  1. Disconnect the control panel cable from the connector on the system board.
  2. Lift the latch to release the control panel cable and slide the cable from the clip.
    NOTE:Observe the routing of the cable as you remove it from the system.
  3. Using the Phillips #1 screwdriver, remove the screws that secure the left control panel to the system.
  4. Hold the left control panel cable, and slide the left control panel out of the system.
    NOTE:The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
    Figure 1. Removing the left control panel
    This image shows how to remove the left control panel.