nve-controller

Assigns the interfaces to be managed by the controller.

Syntax
nve-controller
Parameters
None
Default
None
Command mode
INTERFACE
Usage information
The interface must be in Switchport Trunk mode when adding the interface to the controller. If the interface is not in the Switchport Trunk mode, the system displays the following error message:
% Error: Interface ethernet1/1/1, must be in switchport trunk for controller mode.
NOTE: If the interface has active port-scoped VLAN (Port,VLAN) pairs configured by the controller, you cannot remove an interface from the controller.

The no version of this command removes the interface from the controller and removes any VXLAN binding associated with the interface.

Example
OS10(config)# interface ethernet 1/1/1
OS10(config-if-eth1/1/1)# nve-controller
Supported releases
10.4.3.0 or later