Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

clock summer-time recurring

Set the software clock to convert to daylight saving time on a specific day each year.

Syntax clock summer-time time-zone recurring [ start-week start-day start-month start-time end-week end-day end-month end-time [ offset]]

To delete a daylight saving time zone configuration, use the no clock summer-time command.

Parameters
time-zone Enter the three-letter name for the time zone. This name is displayed in the show clock output. You can enter up to eight characters.
start-week (OPTIONAL) Enter one of the following as the week that daylight saving begins and then enter values for start-day through end-time:
  • week-number: Enter a number from 1 to 4 as the number of the week in the month to start daylight saving time.
  • first: Enter this keyword to start daylight saving time in the first week of the month.
  • last: Enter this keyword to start daylight saving time in the last week of the month.
start-day Enter the name of the day that you want daylight saving time to begin. Use English three letter abbreviations; for example, Sun, Sat, Mon, and so on. The range is from Sun to Sat.
start-month Enter the name of one of the 12 months in English.
start-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm.
end-week Enter the one of the following as the week that daylight saving ends:
  • week-number: enter a number from 1 to 4 as the number of the week to end daylight saving time.
  • first: enter the keyword first to end daylight saving time in the first week of the month.
  • last: enter the keyword last to end daylight saving time in the last week of the month.
end-day Enter the weekday name that you want daylight saving time to end. Enter the weekdays using the three letter abbreviations; for example Sun, Sat, Mon, and so on. The range is from Sun to Sat.
end-month Enter the name of one of the 12 months in English.
end-time Enter the time in hours:minutes:seconds. For the hour variable, use the 24-hour format; example, 17:15:00 is 5:15 pm.
offset (OPTIONAL) Enter the number of minutes to add during the summer-time period. The range is from 1 to 1440. The default is 60 minutes.
Defaults Not configured.
Command Modes CONFIGURATION
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Related Commands

clock summer-time date — sets a date (and time zone) on which to convert the switch to daylight saving time on a one-time basis.

show clock — displays the current clock settings.