Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

rmon hc-alarm

Set an alarm on any MIB object.

Syntax rmon hc-alarm number variable interval {delta | absolute} rising-threshold value event-number falling-threshold value event-number [owner string]

To disable the alarm, use the no rmon hc-alarm number command.

Parameters
number Enter the alarm integer number from 1 to 65535. The value must be unique in the RMON alarm table.
variable The MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object type must be a 64-bit integer.
interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds.
delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table.
absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rising-threshold value event-number Enter the keywords rising-threshold then the value (64 bit) the rising-threshold alarm is either triggered or reset. Then enter the event-number to trigger when the rising threshold exceeds its limit. This value is the same as the alarmRisingEventIndex or alarmTable of the RMON MIB. If there is no corresponding rising-threshold event, the value is zero.
falling-threshold value event-number Enter the keywords falling-threshold then the value (64 bit) the falling-threshold alarm is either triggered or reset. Then enter the event-number to trigger when the falling threshold exceeds its limit. This value is the same as the alarmFallingEventIndex or the alarmTable of the RMON MIB. If there is no corresponding falling-threshold event, the value is zero.
owner string (OPTIONAL) Enter the keyword owner then the owner name to specify an owner for the alarm. This is the alarmOwner object in the alarmTable of the RMON MIB.
Defaults owner
Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.