dot1x supplicant-timeout

Configure the amount of time after which exchanges with the supplicant time-out.

Syntax dot1x supplicant-timeout seconds

To return to the default, use the no dot1x supplicant-timeout command.

Parameters
seconds Enter a time-out value in seconds. The range is from 1 to 300, where 300 is implementation dependant. The default is 30.
Defaults 30 seconds
Command Modes INTERFACE
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.