Configure an SNMPv3 view.

Syntax snmp-server view view-name oid-tree {included | excluded}

To remove an SNMPv3 view, use the no snmp-server view view-name oid-tree {included | excluded} command.

Parameters
view-name Enter the name of the view (not to exceed 20 characters).
oid-tree Enter the OID sub tree for the view (not to exceed 20 characters).
included (OPTIONAL) Enter the keyword included to include the MIB family in the view.
excluded (OPTIONAL) Enter the keyword excluded to exclude the MIB family in the view.
Defaults none
Command Modes CONFIGURATION
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information The oid-tree variable is a full sub-tree starting from 1.3.6 and cannot specify the name of a sub-tree or a MIB. The following Example configures a view named rview that allows access to all objects under 1.3.6.1.
Example
Dell#(conf) snmp-server view rview 1.3.6.1 included
Related Commands show running-config — displays the SNMP running configuration.