show fcoe-map

Displays the Fibre Channel and FCoE configuration parameters in FCoE maps.

Syntax show fcoe-map [ brief | map-name]
Parameters
brief Displays an overview of currently configured FCoE maps.
map-name Displays the FC and FCoE configuration parameters in a specified FCoE map. The FCoE map is applied on Ethernet (FCoE) and FC ports to transmit FC storage traffic to a specified fabric.
Command Modes
  • EXEC
  • EXEC Privilege
Supported Modes All modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module.
Usage Information

Use the show fcoe-map command to display the FC and FCoE parameters used to configure server-facing Ethernet (FCoE) and fabric-facing FC ports in all FCoE maps on an FN 2210S Aggregator with the FC Flex IO module NPIV proxy gateway.

In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN fabric to which FC storage traffic is sent, and the FCoE VLAN to be used must be unique.

The following describes the show fcoe-map brief output shown in the example.

Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC traffic is forwarded.
VLAN ID The dedicated FCoE VLAN used to transport FCoE storage traffic between servers and a fabric over the NPIV proxy gateway. The configured VLAN ID must be the same as the fabric ID.
FC-MAP FCoE MAC address-prefix value - The unique 24-bit MAC address prefix that identifies a fabric.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Config-State Indicates whether the configured FCoE and FC parameters in the FCoE map are valid: Active (all mandatory FCoE and FC parameters are correctly configured) or Incomplete (either the FC-MAP value, fabric ID, or VLAN ID are not correctly configured).
Oper-State Operational status of link to the fabric: Up (link is up and transmitting FC traffic), Down (link is down and not transmitting FC traffic), Link-wait (link is up and waiting for FLOGI to complete on peer FC port), or Removed (port has been shut down).

The following describes the show fcoe-map map-name output shown in the example.

Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC traffic is forwarded.
VLAN ID The dedicated FCoE VLAN used to transport FCoE storage traffic between servers and a fabric over the NPIV proxy gateway. The configured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE traffic uses VLAN priority 3. (This setting is not user-configurable.)
FC-MAP FCoE MAC address-prefix value - The unique 24-bit MAC address prefix that identifies a fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Config-State Indicates whether the configured FCoE and FC parameters in the FCoE map are valid: Active (all mandatory FCoE and FC parameters are correctly configured) or Incomplete (either the FC-MAP value, fabric ID, or VLAN ID are not correctly configured).
Oper-State Operational status of link to the fabric: Up (link is up and transmitting FC traffic), Down (link is down and not transmitting FC traffic), Link-wait (link is up and waiting for FLOGI to complete on peer FC port), or Removed (port has been shut down).
Members FN2210S Aggregator with the FC Flex IO module Ethernet and FC ports that are members of the dedicated FCoE VLAN that carries storage traffic to the specified fabric.
Example
Dell#show fcoe-map brief 
                                             Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config-State Oper-State
                                             test       16      16      0efc02  128         ACTIVE       UP
                                             cnatest    1003   	 1003    0efc03  128        ACTIVE        UP
                                             sitest     1004    1004    0efc04  128         ACTIVE       DOWN
                                             
                                          
                                             Dell#show fcoe-map si 
                                             
                                             Fabric Name        si    
                                             Fabric Id          1004  
                                             Vlan Id            1004  
                                             Vlan priority      3     
                                             FC-MAP             0efc04
                                             FKA-ADV-Period     8     
                                             Fcf Priority       128   
                                             Config-State       ACTIVE  
                                             Oper-State         DOWN   
                                             Members            
                                          
Related Commands

fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers and a SAN fabric.