Dell SupportAssist Version 1.2 for Servers User’s Guide

Manually configuring the alert destination (Linux)

Perform the following steps to manually configure the alert destination of a monitored device running Linux:

  1. Run the command rpm -qa | grep snmp, and ensure that the net-snmp package is installed.
  2. Run cd /etc/snmp to navigate to the snmp directory.
  3. Open snmpd.conf in the VI editor ( vi snmpd.conf).
  4. Search snmpd.conf for # group context sec.model sec.level prefix read write notif and ensure that the values for fields read, write, and notif are set to all.
  5. At the end of the snmpd.conf file, just before Further Information, add an entry in the following format: Trapsink <IP address of the server on which SupportAssist is installed> <community string> For example, trapsink 10.94.174.190 public.
  6. Restart the SNMP services ( service snmpd restart ).