Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

sflow polling-interval (Interface)

Set the sFlow polling interval at an interface (overrides the global-level setting).

Syntax sflow polling-interval interval value

To return to the default, use the no sflow polling-interval interval command.

Parameters
interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is the global counter polling interval .
Defaults The same value as the current global default counter polling interval.
Command Modes INTERFACE
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information This command sets the counter polling interval for an interface.
Related Commands sflow polling-interval (Global) — globally sets the polling interval.