Common symptoms of library autoconfiguration failure include the following:

  • The library is not listed in the Libraries folder in the Administration interface.
  • The library is listed, but is listed as being unconfigured.

Common causes include:

  • Device drivers are not properly installed.
  • Autodetection fails to match a detected library with its devices due to:
    • Out-of-date device firmware.
    • Failure of the library to return its devices’ serial numbers.
  • Autodetection failed to start on the storage nodes.
  1. Check Monitoring > Log for relevant messages.
  2. From the command prompt, type the following command to verify that the library returns the serial numbers of its devices:

    sn -a b.t.l.

    where b.t.l. refers to the bus target LUN of the library. If the bus target LUN is not known, run the inquire command first, to obtain this information.