Troubleshooting storage node affinity issues

If a backup fails because of a problem related to the storage node affinity, a message similar to the following might appear:

no matching devices; check storage nodes, devices or pools

Possible causes for this error message include:

  • No enabled devices are on the storage nodes.
  • The devices do not have volumes that match the pool required by the backup request.
  • All devices are set to read-only or are disabled.

For example, if the client has only one storage node in its Storage Node list, and all devices on that storage node are disabled, fix the problem and then restart the backup.

Complete one of the following actions to fix the problem:

  • Enable devices on one of the storage nodes in the storage node list for the client.
  • Correct the pool restrictions for the devices in the storage node list.
  • Configure an additional storage node that has enabled devices that meet the pool restrictions.
  • Set one of the devices to read/write.