Add a VLAN ID to a Physical iSCSI Fault Domain

Add a VLAN ID to an existing iSCSI fault domain if the ports in the fault domain are connected to a tagged network.

Prerequisites

The Storage Center iSCSI ports must be configured for virtual port mode.

Steps

  1. If the Dell Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
  2. Click the Storage tab.
  3. In the Storage tab navigation pane, expand Fault Domains, then expand iSCSI and click the fault domain.
  4. In the right pane, click Edit Settings.
    The Edit Fault Domain Settings dialog box opens.
  5. Select the VLAN Tagged checkbox.
  6. In the VLAN ID field, type a VLAN ID for the fault domain. Allowed values are 1–4096.
  7. (Optional) To assign a priority level to the VLAN, type a value from 0-7 in the Class of Service Priority field. 0 is best effort, 1 is the lowest priority, and 7 is the highest priority.
  8. Click OK.