Dell Storage Manager 2020 R1 Administrator's Guide

Modify the TCP Port for an iSCSI Fault Domain

By default, iSCSI ports accept iSCSI connections on TCP port 3260. Modify the port as needed to integrate with iSCSI network infrastructure.

Steps

  1. If the Dell Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
  2. Click the Storage tab.
  3. In the Storage tab navigation pane, expand Fault Domains, then expand iSCSI and click the fault domain.
  4. In the right pane, click Edit Settings.
    The Edit Fault Domain Settings dialog box opens.
  5. Click Edit Advanced Port Settings.
    The Edit Advanced Port Settings dialog box opens.
  6. In the Port Number field, type the TCP port to use for iSCSI traffic.
  7. Click OK to close the Edit Advanced Port Settings dialog box.
  8. Click OK.